Unit for Determination of Density
Model H3002

ISO 1183 | DIN 53 479 | ASTM D 792 | BS 2782

Analytic balance with integrated application software and accessories for determination of density according to immersion method



more >>

Density Gradient Column
Model H3002

ISO 1183 | ASTM D 1505

The testing device is according to ASTM D 1505 and is supplied complete with pumped filling system and basket sweep mechanism.



more >>

MFR/MVR Tester
Model 1709

ISO 1133 | DIN 53 735 | ASTM D 1238 | BS 2782

for the determination of the melt flow rate (MFR) and the melt volume- flow rate (MVR) of thermoplastics with operational temperatures up to 450 °C



more >>

MFR Tester
Model 1267

ISO 1133 | DIN 53 735 | ASTM D 1238 | BS 2782

for the determination of the melt flow rate (MFR)  of thermoplastics
with operational temperatures up to 400°C



more >>

Analytical Balance
Model H3000

supplementary unit for performing MFR, carbon black content, K-Value, degree of crosslinking, OIT, volatile matter, water absorption etc..



more >>

Carbon Black Tester
Model 1398

ISO 6964 | DIN 53 585 | ASTM D 1603

for determination of carbon black content of polyolefin pipes and fittings in a compact and breech-proof construction



more >>

Rotational Microtome
Model H3009

ISO 18 553 | ASTM D 5596

mechanical or semi-automatic

This unit is suitable for preparing slices for the assessment of the degree of carbon black dispersion (rugged design;convenient for plastic applications).

 



more >>

Laboratory Microscope
Model H3022

ISO 18 553 | ASTM D 5596

According to the method for the assessment of the degree of pigment dispersion in polyolefin pipes, fittings and compounds a Microscope is used to examine the particles and agglomerates of the test specimens.
Just a few hand movements are required to adjust the microscope to the user‘s seated height, head posture, arm length, and hand sizes. This provides reliable protection from muscular tension, poor posture, and long-term detrimental health effects.



more >>

Moisture Content Unit
Model H3021

ISO 585 | EN 12 118

for determination of the moisture to 0.05 % to 100 % with a system accuracy down to a resolution of 0.1 mg



more >>

Environmental Stress Cracking ESCR
Model H3037

ASTM D 1693

Designed in accordance with ASTM D1693, the apparatus is simple to use and an extremely cost effective method of determining a polymer material‘s susceptibility to stress cracking when exposed to different environments such as soaps, wetting agents, oils and detergents.



more >>

DSC Measuring Unit
Model H3003

ISO/TR 10837 | EN 728 | ASTM D 3417 | ASTM D 3418 |
ASTM D 3895

for determining the OIT of polyolefins



more >>

Unit for Determination of Volatile Matter
Model H3004

ISO 1269 | EN 12 099

Determination of volatile matter



more >>

K-Value Test Instrument
Model H3008

ISO 307 | ISO 1628 | ISO 3105 | DIN 51562

Determination of K-value



more >>

Powder Pourability
Model 1326

ISO 6186 | DIN 53 492 | ASTM D 1895

for determination of the pourability and flow properties of powders



more >>

Powder Pourability
Model 1098

Anger

for determination of the pourability and flow properties of powders for tests according to Anger



more >>

Bulk Density Tester
Model 1132

ISO 60 | ASTM D 1895 | BS 2782

for determination of the apparent density of molding materials



more >>

Laboratory Sieving Machine
Model H3001

ISO 2395 | ISO 3310 | DIN 66 165 | ASTM D 1921 |
ASTM E 11 | BS 410

for determination of the fineness of all kinds of powder or grain-like materials



more >>

Test Unit for Rapid Crack Propagation (RCP/S4-Test)
Model 1629

ISO 13 477

for determination of the critical pressure or critical temperature for rapid crack propagation
in accordance with ISO 13 477 for PE pipes up to 250 mm



more >>

Test Unit for Rapid Crack Propagation (RCP/S4-Test)
Model 1671

ISO 13 477

For determination of the critical pressure or critical temperature for rapid crack propagation



more >>

Notch Milling Machine (SCG)
Model 1653

ISO 13 479

for the preparation of test specimens according to ISO 13 479:
Determination of resistance to crack propagation.
Test method for slow crack growth on notched pipes (notch test)
Diameter range from 63 to 630 mm



more >>

Cone Tester
Model 1680

ISO 13 480

for the preparation of test specimen for determination of resistance to slow crack growth



more >>

Tensile Creep Tester for Tests in Fluids (FNCT)
Model 1598

ISO 16 770

for the determination of environmental stress cracking (ESC) of Polyethylene – Full notch creep test (FNCT)

with 6 stations, 6 tanks and 6 selectable temperatures for tensile loads up to 4000 N



more >>

Chemical Test Unit
Model 1599

ISO 8584-1 | BS 2782

for the determination of the chemical resistance factor and of the basic stress of polyolefine pipes.
With heat modules taking up to 20 specimens



more >>

Test Unit for the Determination of Water Absorption
Model H3005

ISO 62 | ASTM D 570 | BS 2782

Determination of water absorption



more >>